Skip to product information
Water Solutions WS-2M commercial reverse osmosis skid, 4,000 GPD, white powder-coated frame

WS-2M Commercial Reverse Osmosis System – 4,000 GPD, Two-Membrane Skid

Request a quote

Or call 844-928-3710 · Configured to your feed water · Freight quoted with your order · Phoenix-area delivery and installation available

Reliable shipping

Flexible returns

The WS-2M-AF/EC-RC is a two-membrane, 4,000 gallon-per-day reverse osmosis skid: pre-plumbed, pre-wired and factory-assembled for commercial duty. Restaurants, ice and beverage, car wash and spot-free rinse, laboratory feed, boiler and cooling-tower make-up, and light industrial process water. Each unit is configured to your feed water and installation, so you pay for the capacity you need and not for a one-size-fits-all package.

Pricing: every system is quoted to your water and your site. Use the Request a quote button or call 844-928-3710 and tell us your expected daily usage and, if you have it, a recent water test or your city's water report. Freight: quoted with your order. Local delivery and installation are available in the Phoenix area.

Download the WS-M Series brochure (PDF) — all three models on one sheet.

Why this system

  • Real controller, real numbers. The electronic controller continuously monitors permeate TDS so you can see membrane performance at a glance instead of guessing.
  • Protects itself. Pretreatment lockout, low-pressure and storage-tank inputs stop the pump before damage happens. The pump will never run dry.
  • Built to last. Powder-coated aluminum frame, multi-stage stainless pump, stainless membrane housings, stainless feed valve, and pump-pressure gauges you can actually read.
  • Serviceable. Open frame layout, standard 20" big-blue pre-filter, standard 4" × 40" TFC membranes. No proprietary consumables.
  • Low cost to run. Low-energy membranes and a concentrate recycle line bring recovery up to 60–75%, so less water goes to drain.
  • Upgradeable. Heavy-duty vertical multi-stage pump packages and a three-phase control module with motor-matched overcurrent protection are available for demanding sites.

Specifications — WS-2M

Rated production 4,000 GPD (10.4 LPM)
Membranes (2) 4" × 40" TFC
Recovery rate Up to 60%
Pump motor ¾ HP
Voltage / frequency 115 V or 230 V · 60 Hz
Full-load amps 13 A (115 V) · 6.5 A (230 V)
Feed water connection ¾" FIP
Permeate outlet ½" compression
Pre-filter cartridge 20" × 4.5" BB · 5 / 50 µm
Flow meters Permeate and concentrate standard; recycle flow meter optional
Concentrate recycle line Standard
Low-pressure switch Standard
Frame Powder-coated aluminum, black or white
Dimensions (H × L × W) 59" × 26" × 18"

Feed water and operating limits

Feed water temperature 40–85 °F (4–29 °C)
Ambient temperature 40–120 °F (4–49 °C)
Feed water pressure 45–85 psi (3.1–5.9 bar)
Max. operating pressure 150 psi (10.3 bar)
Maximum SDI < 3
Maximum turbidity 1 NTU
Maximum free chlorine 0 ppm
Maximum feed TDS 2,000 ppm
Maximum hardness 0 gpg (measured at the RO inlet, after pretreatment)
pH, continuous operation 5–11
pH, cleaning (30 min max.) 2–12

Pretreatment is part of the package. Hardness and chlorine are the two things that shorten membrane life, so every system we install goes in with a softener and carbon filtration sized to the local water.

Standard features

  • Electronic controller with permeate TDS monitoring
  • Powder-coated aluminum frame, black or white
  • 20" big-blue 5-micron sediment pre-filter
  • Stainless steel multi-stage pump
  • Low-energy TFC membranes in stainless steel housings
  • Stainless steel feed valve and pump-pressure gauges
  • Permeate and concentrate flow meters, recycle line, low-pressure switch

Controller

  • 4-line LCD with plain-language status readout
  • Inputs for pretreatment lockout, low feed pressure, and storage-tank level
  • Pump-delay start; the pump will never run dry
  • 4 adjustable program cycles, USB configurable

Options

  • Fiberglass membrane housings
  • Concentrate recycle valve and recycle flow meter
  • Feed water TDS conductivity probe
  • Feed water flush valve
  • Stainless steel pump upgrade or heavy-duty vertical multi-stage pump
  • High-pressure tank switch
  • Permeate sample port
  • TDS blending valve
  • Alternate voltage motors
  • Three-phase control module with pump overcurrent protection set to the actual motor amp draw

Rating conditions: 550 ppm TDS municipal feed water, 5-micron filtered and de-chlorinated, 65 psi (4.5 bar) feed, 100 psi (6.9 bar) operating pressure, 77 °F (25 °C), 7.0 pH, recovery as stated, after 60 minutes of operation. Colder feed water and higher TDS reduce production; we run a projection for your actual water before quoting. Scale prevention (softening or antiscalant) is required to protect membrane life.

Model code key — WS-#M-AF/EC-RC: #M = number of 4" × 40" TFC membranes · AF = powder-coated aluminum frame · EC = electronic controller with TDS monitor · RC = concentrate recycle line.